ELECTRO-CHEMICAL DEVICES
LIQUID MEASUREMENT EXPERT
Available at Alpha Process Sales - Louisiana
-
Sensors
-
Transmitter
-
Analyzers
-
Meters
LEARN MORE
Full
Catalog
Short Form Product Catalog
ECD FEATURED PRODUCT
The Model H10, pH/ORP/Temperature meter and the Model H10C, Conductivity/Salinity/TDS/Temperature meter are battery powered microprocessor based precision instruments. The Model H10 features auto buffer recognition during calibration, automatic temperature compensation and it monitors the electrode’s slope and offset reporting the electrodes efficiency. The Model H10C uses a 4 wire conductivity electrode that measures from 0.001 to 200 mS. The H10C features automatic temperature compensation, auto ranging and user adjustable temperature and TDS coefficients.
BROCHURE
WASTEWATER
BROCHURE
Seawater Dechlorination Analyzer – Model DCA-23
Free Chlorine Analyzer – Model FC80
S80 Intelligent Sensors – Inductive Conductivity
Seawater Dechlorination Analyzer – Model DCA-23
S80 TOROIDAL CONDUCTIVITY
Intelligent Sensor: Stores Identity and Calibration Information
Wide Dynamic Measurement Range: One Sensor for multiple applications
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
The S80 Inductive Conductivity Sensors convert the analog signals from the magnetic toroids into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
S88 Hazardous Location Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Replaceable Electrode Cartridges: Application Specific Solution
Replaceable Electrode Cartridges: Low cost of Ownership
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
The S88 pH Sensors are one part of the Model S88 Intelligent Sensors product line. The S88 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S88 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S88 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership.
S80 Intelligent Sensors – pH Sensor
Intelligent Sensor: Stores Identity and Calibration Information
Replaceable Electrode Cartridges: Application Specific Solution
Replaceable Electrode Cartridges: Low cost of Ownership
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction. The S80 pH Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation from the factory.
The S80 pH Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
S80 Intelligent Sensors – ORP Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Replaceable Electrode Cartridges: Application Specific Solution
Replaceable Electrode Cartridges: Low cost of Ownership
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
Measurement range: -1500 mV – +1500 mV
Temperature range: -10° – 90°C
Wetted Materials: 316L SS, PEEK or PES (electrode body), Teflon, VITON
The S80 ORP Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation.
The S80 ORP Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
S80 Intelligent Sensors – Ion Selective Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Replaceable Electrode Cartridges: Application Specific Solution
Replaceable Electrode Cartridges: Low cost of Ownership
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
Measurement range: Specific to each electrode type
Temperature range: 0° – 80°C solid state style, 0° – 40°C PVC membrane style
Wetted Materials: 316L SS, Teflon, VITON, PVC, PEEK or Radel (electrode body)
The S80 Ion Selective Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation.
The S80 Ion Selective Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
S80 Intelligent Sensors – Conductivity Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Wide Dynamic Measurement Range: One Sensor for multiple applications
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
Measurement range: 50 μS – 50 mS
Temperature range: -20° – 130°C
Wetted Materials: 316L SS, PEEK, VITON
The S80 Conductivity Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation.
The S80 Conductivity Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
S80 Intelligent Sensors – Resistivity Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
Measurement range: 0.00-50.00 meg-ohms
Temperature range: -20° – 130°C
Wetted Materials: 316L SS, PEEK, VITON
The S80 Resistivity Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation.
The S80 Resistivity Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The type of sensor, identity and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer configuring the displays and outputs to the values appropriate to the sensor’s measured parameter.
S80 Intelligent Sensors – Dissolved Oxygen Sensors
Intelligent Sensor: Stores Identity and Calibration Information
Replaceable Electrode Cartridges: Application Specific Solution
Replaceable Electrode Cartridges: Low cost of Ownership
Insertion/Submersion with adjustable gland fittings and Valve Retractable Designs
Wide Variety of Materials of Construction
Measurement range: 0.00-20.00 ppm (mg/l)
Temperature range: -10° – 60°C
Wetted Materials: 316L SS, PEEK, VITON, PFA membrane, Silicone
The S80 Dissolved Oxygen Sensors are one part of the Model S80 Intelligent Sensors product line. The S80 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S80 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation.
The S80 Dissolved Oxygen Sensors convert the analog signals from the electrode cartridge into a digital protocol that allows two way communications with the transmitter. The identity of sensor, measurement type and serial number, are stored in the sensor’s memory along with three calibration registers. When connected to an ECD digital analyzer the sensor’s information is uploaded to the analyzer. This configures the displays and outputs of the transmitter to the values appropriate to the sensor’s measured parameter.
Pre-pHault Diagnostic
SENTINEL technology allows the Model S80 Sensor and T80 Transmitter Series to provide Pre-pHault diagnostic information about the lifetime of a pH, ORP or pIon measurement. The easy-to-read SENTINEL display graphically shows a filled triangular gauge that decreases proportionally to the degradation of the reference electrode. A filled gauge indicates a new electrode that is functioning properly while an empty gauge indicates an electrode near the end of its useable life. In addition to the graphics, the SENTINEL information is remotely transmitted by various user selected outputs providing an alert notification that the sensor electrode is nearing its useful life and will need replacement to avoid down time
Universal Transmitter – Model T80 Series
DOWNLOAD
Universal Transmitter: measures pH, ORP, DO, Specific Ion, Turbidity, Conductivity or Resistivity | Graphic LCD Display: Easy to Read Graphical and Numerical Information
Simple Menu Structure: Intuitive, Easy to Navigate and Configure | Use with ECD Digital Intelligent Sensors that are factory calibrated sensors and store data | 4-20 mA output with MODBUS RTU and Alarm Relays: Flexible configurations for all applications | HART® communication. | Multiple Mounting Configurations — Pipe or Wall Mount | The ECD Universal Transmitter – Model T80 Series is a single or dual channel transmitter designed for the continuous measurement of pH, ORP, pION, Dissolved Oxygen, Turbidity, Conductivity or Resistivity in a general purpose industrial environment. The Model T80 transmitter digitally communicates with any ECD Model S80 Intelligent Sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter.
Hazardous Location Transmitter – Model X80 Series
DOWNLOAD
Universal Transmitter: measures pH, ORP, DO, Specific Ion, Turbidity, Conductivity or Resistivity | Graphic LCD Display: Easy to Read Graphical and Numerical Information
Simple Menu Structure: Intuitive, Easy to Navigate and Configure | Use with ECD Digital Intelligent Sensors that are factory calibrated sensors and store data | Non-intrusive calibration — no need open the enclosure or de-classify area | 4-20 mA output with MODBUS RTU and Alarm Relays: Flexible configurations for all applications | HART® communication | Multiple Mounting Configurations — Pipe or Wall Mount | Explosion-proof / Exd – ATEX and IECEx Approved | Explosion-proof – FM Approved | The ECD Hazardous Location Transmitters – Model X80 Series provides the same capabilities and general feature set as the general purpose T80 Universal Transmitter. Various configurations are available as single or dual channel for the continuous measurement of pH, ORP, pION, Dissolved Oxygen, Turbidity, Conductivity or Resistivity. The Model X80 transmitter digitally communicates with any ECD Model S88 and/or S80 Intelligent Sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. The X80 is designed with a durable stainless steel enclosure for explosion proof/exd hazardous applications.
Turbidity Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Ion Selective, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 Turbidity Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Turbidity Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 Turbidity transmitter will automatically configure to any of the listed measurements.
Resistivity Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Ion Selective, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 Resistivity Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Turbidity Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 Resistivity transmitter will automatically configure to any of the listed measurements.
Conductivity Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Ion Selective, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 Conductivity Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Turbidity Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 Conductivity transmitter will automatically configure to any of the listed measurements.
Dissolved Oxygen Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Ion Selective, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 Dissolved Oxygen Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Turbidity Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 Dissolved Oxygen transmitter will automatically configure to any of the listed measurements.
Ion Selective Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Ion Selective, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 Ion Selective Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Turbidity Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 Ion Selective transmitter will automatically configure to any of the listed measurements.
ORP Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 ORP Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 ORP transmitter will automatically configure to any of the listed measurements.
pH Transmitter – Model T80 Universal
Multi-Parameter, pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure | Noise free digital communication with sensors
Reads and writes calibration data to sensor | Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections… | Isolated 4-20 mA output and MODBUS® RTU standard, optional HART® | The Model T80 pH Transmitter is one part of the Model T80 Universal Transmitter product line. The T80 Transmitter offering includes the pH Transmitter, ORP Transmitter, Ion Selective Transmitter, Dissolved Oxygen Transmitter, Conductivity Transmitter and Resistivity Transmitter. The T80 Transmitters are available as single channel or dual channel instruments. The Model T80 transmitter digitally communicates with any ECD S80 digital sensor, automatically configuring the transmitter’s menus and display screens to the measured parameter. There is no longer a need to inventory multiple instrument types, the one Model T80 pH transmitter will automatically configure to any of the listed measurements.
Hazardous Location Transmitters – Model T28 Series
DOWNLOAD
The Hazardous Location Transmitters – Model T28 Series is a loop powered two-wire process transmitter that has been designed and manufactured to provide liquid process measurement and control in hazardous locations. A choice of measurement parameters include: pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity or Resistivity. With its highly intelligent microprocessor design and durable stainless steel enclosure, the T28 is explosion proof and intrinsically safe, simple to install, calibrate for use in demanding hazardous applications.
Multi Channel Controller – LQ800
DOWNLOAD
Multiple Analytical & Process Measurements | Complete Measuring & Control System: Up to 8 | Smart Digital Analytical & Process Sensors | Touch Screen Color Display |
Easy Intuitive Menu Navigation | Built-in Analytical Calculations | Easy Selectable Mathematic Functions: Automatic measurement conversions for dissociation,
cross-sensitivity, concentration | Multiple Outputs | Field Programmable Outputs: Digital | Communication, Multiple Relays, Discrete Digital | Outputs, 4-20 mA Outputs, Data Logging | Expandable | Create Larger Control Systems: Inter-Connect to other LQ800 Systems and ECD On-Line Analyzers | Web Enabled | Access via Web: Remote Monitoring and Interface with Personal Handheld Devices
Free Chlorine Analyzer – Model FC80
DOWNLOAD
The ECD FC80 Free Chlorine Analyzer is a panel mounted, ready to use Free Chlorine Analyzer. It is designed to monitor free chlorine (residual chlorine) in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine in the range of 0.05-20 ppm Cl2 (High Range) or 0.01 to 5.00 Cl2 (Low Range). The FC80 Free Chlorine Analyzer features a plug and play design that incorporates a flow control device, a pH sensor, a chlorine sensor and the T80 transmitter are conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use. The FC80 Free Chlorine Analyzer is calibrated at the factory before shipment, additional Calibrations are accomplished by DPD comparison.
Total Chlorine Analyzer – Model TC80
DOWNLOAD
The ECD TC80 Total Chlorine Analyzer is a panel mounted, ready to use Total Chlorine Analyzer. It is designed to monitor total chlorine in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine in the range of 0-20 ppm. The Total Chlorine Sensor (TCS) is a three electrode amperometric sensor that measures all chlorine species in the water, combined chlorine and free chlorine in a range of 0.05 – 20 ppm Cl2 (High Range) or 0.005 to 2.000 ppm (Low Range). The TC80 Total Chlorine Analyzer features a plug and play design that incorporates a flow control device, a pH sensor, a chlorine sensor and the T80 transmitter are conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use. The TC80 Total Chlorine Analyzer is calibrated at the factory before shipment, additional Calibrations are accomplished by DPD comparison.
Chlorine Dioxide Analyzer – Model CD80
The ECD CD80 Chlorine Dioxide Analyzer is a panel mounted, ready to use Chlorine Dioxide Analyzer. It is designed to monitor Chlorine Dioxide (ClO2) in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine dioxide in the range of 0.05 to 20 ppm. The CD80 Chlorine Dioxide Analyzer features a plug and play design that incorporates a flow control device, a chlorine dioxide sensor and the T80 transmitter that are conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use.
Seawater Dechlorination Analyzer – Model DCA-23
DOWNLOAD
Single purpose analyzer designed to monitor the chlorination and/or dechlorination of sea water from 0.00 – 2.00 ppm. The DCS-23 Seawater Dechlorination Analyzer comes complete with T23 Transmitter, sensors, piping and valves ready for an easy plumb and play installation. Just connect the water inlet and outlet, and electrical connections of power and transmitter output. The DCA-23 provides an accurate and economical solution to the measurement of chlorine in seawater used in heat exchangers or at desalination plants.
DeChlorination Analyzer – Model DC80
The ECD DC80 DeChlorination Analyzer is a panel mounted, ready to use DeChlorination Analyzer. It is designed to monitor very low levels of Total Chlorine water to measure that chlorine has been removed within an allowable level before discharging or releasing water into the environment. The DC80 DeChloinration Analyzer has all of the advantages of ECD’s TC80 Total Chlorine Analyzer and uses a “zero shift” strategy to make the measurement. Since the total chlorine amperometric needs some amount of chlorine for a stable reading, the ECD DC80 pump supplies a constant 3 to 5 ppm of total chlorine and the DC80 DeChlorination Analyzer “zeros” out this offset to measure the difference of the water to be measured compared to the total chlorine supplied. This results in a very stable, very low level Total Chlorine measurement to verify that total chlorine has been removed. The DC80 DeChlorination Analyzer features a plug and play design that incorporates a flow control device, a total chlorine sensor, pH sensor, and the T80 transmitter that are conveniently mounted on a PVC panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use.
HCA1 PORTABLE COLORIMETRIC CHLORINE TEST KIT
Ideal for testing Free and Total Chlorine in drinking water, waste water, environmental waters, cooling towers and rinse waters in the food and beverage industry. The Portable Colorimetric Chlorine Test Kit is designed to use the Micro Strip reagent delivery system. The kit is supplied with 100 test strips for Free Chlorine and 100 test strips for Total Chlorine. Test strips for Combined Chlorine, Chlorine Dioxide, High Range Chlorine, and Peracetic Acid are also available for the HCA1 Chlorine Plus meter.
Free Chlorine Sensors, Total Chlorine Sensors and Chlorine Dioxide Sensors
Free, Total and Chlorine Dioxide and Flow Cells are available as separate components for users who do not want to use the complete panel mounted system. Choose only the components needed for the specific application, Analyzer, Sensors and/or Flow Cells. Components are listed on the data sheets for each of the various chlorine products.
Hazardous Location Free Chlorine Analyzer – Model FCX80
The FCX80 is a panel mounted, ready to use Free Chlorine Analyzer intended for hazardous locations. It is designed to monitor free chlorine in drinking water, rinse water, cooling water or other water samples from 0.05 – 20 ppm chlorine as the standard range or 0.01 – 5.00 ppm with the low range sensor. The FCX80 is compliant with EPA method 334.0 for measuring drinking water. The FCX80 features a plug and play design that incorporates a constant head flow control device, a pH sensor, a chlorine sensor and the X80 analyzer/ transmitter conveniently mounted on a panel. Connect the sample and drain lines, connect the power and outputs and it is ready to use. Calibration is accomplished by DPD comparison. Free chlorine exists in solution as a pH dependent ratio of hypochlorous acid (~100% at pH 5) and hypochlorite ion (~100% at pH 10).